1 Water, Energy, Environment and Industrial Processes Laboratory (LE3PI), Cheikh Anta Diop University, Dakar, Senegal.
2 Laboratory for Teaching and Research in Energy, Automation and Telecommunications (LENAT), UGANC, Conakry, Guinea.
3 GREAH Laboratory, University of Le Havre Normandie, 75 Rue Bellot, 76600 Le Havre, France.
4 Department of Electrical Engineering of the Polytechnic Institute, University Gamal Abdel Nasser de Conakry (UGANC), Conakry, Guinea.
* Corresponding Author
ORCID Details
Souleymane SOUMAH: https://orcid.org/0009-0002-1280-5570
Mouhamadou Falilou NDIAYE: https://orcid.org/0000-0002-9421-7598
Mohamed Ansoumane CAMARA: https://orcid.org/0009-0009-0922-3415
Mohamed Lamine TOURE: https://orcid.org/0009-0008-6307-0715
Kadiatou Aissatou BARRY: https://orcid.org/0009-0005-0204-9021
Vincent SAMBOU: https://orcid.org/0000-0002-1042-8348
World Journal of Advanced Research and Reviews, 2026, 32(01), 944–960
Article DOI: 10.30574/wjarr.2026.32.1.2592
Received on 02 September 2026; revised on 12 October 2026; accepted on 14 October 2026
Energy management is a key factor in the reliability and performance of photovoltaic (PV) systems coupled with battery storage for rural electrification. Unlike studies based on representative days, this work investigates the operation of a PV–battery system over a continuous 28-day period (672 h) to assess the influence of day-to-day weather variations on its behaviour. The system consists of a 36.6 kWp PV generator, a battery storage system (648 Ah, 200 V), and a bidirectional buck–boost converter exchanging energy between the DC bus and the batteries. Simulations were carried out in MATLAB/Simulink using hourly solar irradiation and temperature profiles measured in Senegal in February 2005, and a domestic load profile. Maximum power point tracking is performed with the incremental conductance algorithm, while a PI controller maintains the DC bus voltage at its 395 V reference. A rule-based energy management strategy coordinates PV generation, storage and load supply according to the instantaneous power balance and the battery state of charge (SOC). Results show that the DC bus voltage remains globally close to its reference despite fluctuations in solar irradiation, apart from a transient drop to about 260 V around 275 h. The battery SOC stays close to 50% over the whole month, indicating stable operation of the strategy under the simulated conditions. This study provides a basis for analysing the sizing and operation of PV–battery systems in the sub-Saharan African context.
Photovoltaic-battery system; Energy management; Rural microgrid; Solar water pumping; Battery storage; MPPT control
Preview Article PDF
Souleymane SOUMAH, Mouhamadou Falilou NDIAYE, Mohamed Ansoumane CAMARA, Mohamed Lamine TOURE, Kadiatou Aissatou BARRY and Vincent SAMBOU. RULE-BASED ENERGY MANAGEMENT OF A STANDALONE PV-BATTERY SYSTEM UNDER ONE-MONTH SOLAR RESOURCE VARIABILITY: A CASE STUDY IN SENEGAL. World Journal of Advanced Research and Reviews, 2026, 32(01), 944–960. Article DOI: https://doi.org/10.30574/wjarr.2026.32.1.2592