Department of Architecture, Faculty of Architecture, Bingham University, Karu, Nasarawa State, Nigeria.
* Corresponding Author: Sharon Ene Ochigbo
ORCID Details
Sharon Ene Ochigbo: https://orcid.org/0009-0009-2141-3684
Daniel Labaran Abalaka: https://orcid.org/0009-0007-3260-5345
Ruth Rakiya Martins: https://orcid.org/0000-0001-9285-5839
World Journal of Advanced Research and Reviews, 2026, 31(03), 657–665
Article DOI: 10.30574/wjarr.2026.31.3.2333
Received on 31 July 2026; revised on 09 September 2026; accepted on 11 September 2026
Contemporary institutional libraries in Nigeria face increasing pressure to maintain thermal and visual comfort while limiting dependence on energy-intensive mechanical cooling. Although passive and biophilic strategies are increasingly discussed in Nigerian architectural research, evidence on how these strategies are integrated within institutional libraries remains fragmented. This study comparatively assesses six library precedents; three Nigerian cases and three international benchmarks using a Precedent Extraction Protocol (PEP) that examines seven architectural categories: courtyard integration, atrium/stack ventilation, vegetation integration, shading, cross ventilation, daylighting, and façade environmental control. The assessment indicates that the Nigerian cases demonstrate particular strengths in daylighting (median 5) and cross ventilation (median 4), while façade environmental control (median 2; range 1–4), atrium/stack ventilation (median 2; range 2–4), and vegetation integration (median 3; range 2–3) show greater limitations. These findings suggest that the key challenge is not the absence of passive or biophilic measures, but their incomplete coordination across the building envelope, landscape, and ventilation systems. The principal practical contribution of the study is a proposed integrated library design matrix that links façade control, shading, vegetation, courtyard planning, daylighting, and stack-assisted ventilation into a coordinated design approach. The matrix provides a context-sensitive basis for developing and evaluating future Nigerian institutional library briefs and designs. The PEP is used as a comparative design-assessment tool rather than a substitute for measured environmental performance.
Biophilic Design, Institutional Libraries, Passive Cooling, Precedent Analysis, Thermal Performance
Preview Article PDF
Sharon Ene Ochigbo, Daniel Labaran Abalaka and Ruth Rakiya Martins. PASSIVE COOLING AND BIOPHILIC PERFORMANCE IN CONTEMPORARY NIGERIAN INSTITUTIONAL LIBRARIES: A COMPARATIVE PRECEDENT ANALYSIS. World Journal of Advanced Research and Reviews, 2026, 31(03), 657–665. Article DOI: https://doi.org/10.30574/wjarr.2026.31.3.2333