Development of cardiac phantom which mimics the heart function using a 4.7t preclinical MRI system for cardiac imaging

Breadcrumb

  • Home
  • Development of cardiac phantom which mimics the heart function using a 4.7t preclinical MRI system for cardiac imaging

Eze BE 1, *, Ettah EB 1, Ushie, PO 1, Bassey AE 2 and Igomah GO 3

1 Department of Physics, Cross River University of Technology, Calabar, Nigeria.
2 Department of Sociology (Medical), University of Calabar, Calabar, Nigeria.
3 Department of Physics, University of Calabar, Calabar, Nigeria.
 
Research Article
World Journal of Advanced Research and Reviews, 2023, 18(03), 256-263
Article DOI: 10.30574/wjarr.2023.18.3.0463
DOI url: https://doi.org/10.30574/wjarr.2023.18.3.0463
 
Received on 22 April 2023; revised on 02 June 2023; accepted on 04 June 2023
 
Cardiac MRI was one of the first MRI applications in the 1980s, which helps in the human study of different cardiovascular diseases. MRI is a noninvasive imaging technique that can be used for diagnosis and has advantages over other imaging techniques since it does not rely on radiation like X-rays, PET, and SPECT. Modern clinical methods do not require much scanning time, it revels good contrast between tissues and can compensate for patient movement during the scan. The scanner used is a 300mm internal diameter superconducting magnet (Magnex Uk) 4.7T preclinical MRI system, in the Biomedical Physics building at the University of Aberdeen. The cardiac phantom is made of a balloon filled with water, connected via a nylon T-piece to two 5 m lengths of rigid pvc tubing of 3 mm internal diameter to a 12 V water pump and solenoid valve located outside the 4.7 T MRI system’s 5 Gauss stray field contour. The balloon part of the phantom was fixed on the 4.7 T MRI system’s animal bed, directly over a 30mm diameter surface coil normally used to image the rat heart. The flow system was primed with water to mimic blood and the bed was loaded into the MRI magnet for imaging. The cardiac phantom has successfully been developed using a small balloon to represent a heart chamber and imaged in a 4.7T preclinical MRI scanner.  Images acquired with gradient echo pulse sequence with shorter TE of 5 ms and using surface coil displayed improved image contrast and have useful signal-to-noise ratio as compared to images acquired with birdcage coil which show ghosting artifact.
 
Cardiac phantom; Heart function; Cardiac imaging; Balloon phantom; 4.7T MRI; Heart chamber; Preclinical MRI.
 
https://wjarr.com/sites/default/files/fulltext_pdf/WJARR-2022-0463.pdf

Preview Article PDF

Eze BE, Ettah EB, Ushie, PO, Bassey AE and Igomah GO. Development of cardiac phantom which mimics the heart function using a 4.7t preclinical MRI system for cardiac imaging. World Journal of Advanced Research and Reviews, 2023, 18(3), 256-263. Article DOI: https://doi.org/10.30574/wjarr.2023.18.3.0463

Copyright © Author(s). All rights reserved. This article is published under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0), which permits use, sharing, adaptation, distribution, and reproduction in any medium or format, as long as appropriate credit is given to the original author(s) and source, a link to the license is provided, and any changes made are indicated.


All statements, opinions, and data contained in this publication are solely those of the individual author(s) and contributor(s). The journal, editors, reviewers, and publisher disclaim any responsibility or liability for the content, including accuracy, completeness, or any consequences arising from its use.

Get Certificates

Get Publication Certificate

Download LoA

Check Corssref DOI details

Issue details

Issue Cover Page

Editorial Board

Table of content

Copyright © 2026 World Journal of Advanced Research and Reviews - All rights reserved

Developed & Designed by VS Infosolution