Home
World Journal of Advanced Research and Reviews
International Journal with High Impact Factor for fast publication of Research and Review articles

Main navigation

  • Home
    • Journal Information
    • Editorial Board Members
    • Reviewer Panel
    • Abstracting and Indexing
    • Journal Policies
    • Our CrossMark Policy
    • Publication Ethics
    • Issue in Progress
    • Current Issue
    • Past Issues
    • Instructions for Authors
    • Article processing fee
    • Track Manuscript Status
    • Get Publication Certificate
    • Join Editorial Board
    • Join Reviewer Panel
  • Contact us
  • Downloads

eISSN: 2581-9615 || CODEN: WJARAI || Impact Factor 8.2 ||  CrossRef DOI

Research and review articles are invited for publication in April 2026 (Volume 30, Issue 1) Submit manuscript

Comparative validity of left ventricular ejection fraction measured by M-mode versus three-dimensional echocardiography: A prospective observational study

Breadcrumb

  • Home
  • Comparative validity of left ventricular ejection fraction measured by M-mode versus three-dimensional echocardiography: A prospective observational study

Tulika Kumari 1, 2, * and Deepak Kumar Parhi 1

1 Department of Cardiology, IMS and SUM Hospital, Bhubaneswar, Odisha, India. 

2 Department of Medicine, MGM Medical College and Hospital, Jamshedpur, Jharkhand, India.

Research Article

World Journal of Advanced Research and Reviews, 2026, 30(01), 295-302

Article DOI: 10.30574/wjarr.2026.30.1.0818

DOI url: https://doi.org/10.30574/wjarr.2026.30.1.0818

Received on 24 February 2026; revised on 31 March 2026; accepted on 02 April 2026

Background: Accurate assessment of left ventricular ejection fraction (LVEF) is essential for the diagnosis, risk stratification, and management of cardiovascular disease. Although M-mode echocardiography remains widely used due to its simplicity and accessibility, it relies on geometric assumptions and one-dimensional measurements. Three-dimensional (3D) echocardiography enables direct volumetric assessment without geometric assumptions and is recommended by contemporary imaging guidelines. This study aimed to evaluate the validity and agreement of M-mode–derived LVEF compared with 3D echocardiographic LVEF.

Methods: In this prospective observational study, 200 consecutive adult patients undergoing transthoracic echocardiography were enrolled. LVEF was measured using M-mode (Teichholz method) and 3D echocardiography. Correlation between methods was assessed using Pearson correlation coefficient. Agreement was evaluated using Bland–Altman analysis. Diagnostic performance of M-mode LVEF for identifying reduced systolic function (LVEF <50%) was assessed using receiver operating characteristic (ROC) analysis.

Results: A total of 200 patients were included, of whom 198 had complete paired measurements (mean age 57.1 ± 10.9 years; 69.7% male). Mean LVEF measured by M-mode was 51.1 ± 11.8%, whereas mean LVEF measured by 3D echocardiography was 54.5 ± 10.9%. M-mode–derived LVEF demonstrated a strong positive correlation with 3D LVEF (r = 0.911, p < 0.001). However, Bland–Altman analysis revealed a mean bias of −3.37% with wide limits of agreement (−12.95% to +6.20%), indicating poor agreement between methods. M-mode LVEF demonstrated excellent diagnostic performance for identifying reduced systolic function, with an area under the curve of 0.973. An optimal cutoff of 48% yielded a sensitivity of 98.4% and specificity of 82.5%.

Conclusions: Although M-mode–derived LVEF demonstrates strong correlation with 3D echocardiography, it shows significant bias and wide limits of agreement, limiting its clinical interchangeability. Three-dimensional echocardiography provides a more accurate and reliable assessment of left ventricular systolic function and should be preferred in contemporary clinical practice.

Left ventricular ejection fraction; M-mode echocardiography; Three-dimensional echocardiography; Bland–Altman analysis; Diagnostic accuracy; ROC analysis; Left ventricular systolic function

https://wjarr.com/sites/default/files/fulltext_pdf/WJARR-2026-0818.pdf

Preview Article PDF

Tulika Kumari and Deepak Kumar Parhi. Comparative validity of left ventricular ejection fraction measured by M-mode versus three-dimensional echocardiography: A prospective observational study. World Journal of Advanced Research and Reviews, 2026, 30(01), 295-302. Article DOI: https://doi.org/10.30574/wjarr.2026.30.1.0818.

Copyright © Author(s). All rights reserved. This article is published under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0), which permits use, sharing, adaptation, distribution, and reproduction in any medium or format, as long as appropriate credit is given to the original author(s) and source, a link to the license is provided, and any changes made are indicated.


All statements, opinions, and data contained in this publication are solely those of the individual author(s) and contributor(s). The journal, editors, reviewers, and publisher disclaim any responsibility or liability for the content, including accuracy, completeness, or any consequences arising from its use.

Get Certificates

Get Publication Certificate

Download LoA

Check Corssref DOI details

Issue details

Issue Cover Page

Editorial Board

Table of content

Copyright © 2026 World Journal of Advanced Research and Reviews - All rights reserved

Developed & Designed by VS Infosolution