Home
World Journal of Advanced Research and Reviews
International Journal with High Impact Factor for fast publication of Research and Review articles

Main navigation

  • Home
    • Journal Information
    • Editorial Board Members
    • Reviewer Panel
    • Abstracting and Indexing
    • Journal Policies
    • Our CrossMark Policy
    • Publication Ethics
    • Issue in Progress
    • Current Issue
    • Past Issues
    • Instructions for Authors
    • Article processing fee
    • Track Manuscript Status
    • Get Publication Certificate
    • Join Editorial Board
    • Join Reviewer Panel
  • Contact us
  • Downloads

eISSN: 2581-9615 || CODEN: WJARAI || Impact Factor 8.2 ||  CrossRef DOI

Research and review articles are invited for publication in April 2026 (Volume 30, Issue 1) Submit manuscript

Comparative evaluation of tensile bond strength of auto polymerising and heat cure soft liner with different denture base resins after surface treatment: An in vitro study

Breadcrumb

  • Home
  • Comparative evaluation of tensile bond strength of auto polymerising and heat cure soft liner with different denture base resins after surface treatment: An in vitro study

C Pradeep *, Manesh Lahori and Siddharth Sisodiya

Department of Prosthodontics, Crown & Bridge and Implantology, Kd Dental College, Mathura, India.
Research Article
World Journal of Advanced Research and Reviews, 2022, 16(03), 711-722
Article DOI: 10.30574/wjarr.2022.16.3.1381
DOI url: https://doi.org/10.30574/wjarr.2022.16.3.1381
Received on 06 November 2022; revised on 20 December 2022; accepted on 23 December 2022
Aim: To compare the bond strength of the auto polymerising and heat cure soft liner bonded to the Different heat cure acrylic denture base resins
Materials and methods: One silicone based autopolymerising soft liner (Mollosil) and one silicon based heat polymerized soft liners (Molloplast-B ) were used in this study one twenty specimens (30mm x 10mm x10mm) were fabricated in stainless steel molds for testing Tensile strength. 240 blocks randomly divided into 12 groups, each group contained 20 blocks to fabricated 10 specimens per group. The specimen preparation and test for Tensile strength were carried out in accordance with the ISO Specification No. 10139 for soft denture liners.
Result: The Mean Tensile bond strength was found to be highest (3.20 Mpa) for Group12 - PMMA (Trevelon) after Surface treatment with MMA and alumina particles packed with Molloplast – B Mollosil - Mean Tensile bond strength of Group 1,2,3(control group) was found to be less than Group 7,8,9( after surface treatment). Mollopast B - Mean Tear bond strength of Group 4,5,6 (control group) was found to be less than Group 10,11,12 (after surface treatment) The lowest Tensile bond strength was found to be of Group 2 - non treated PMMA Ashwin ( 1.22 Mpa)
Conclusion: Bond strength of Molloplast-B was greater than bond strength of Mollosil.
Bond strength of Molloplast-B packed against denture base trevalon after surface treatment was even greater than the bond strength of Molloplast-B bonded with trevalon without surface treatment. The lowest tensile bond strength was seen with Mollosil cured against denture base Ashwin.
Soft liners; Silicon based soft liners; Mollosil; Molloplast-b
https://wjarr.com/sites/default/files/fulltext_pdf/WJARR-2022-1381.pdf

Preview Article PDF

C Pradeep, Manesh Lahori and Siddharth Sisodiya. Comparative evaluation of tensile bond strength of auto polymerising and heat cure soft liner with different denture base resins after surface treatment: An in vitro study. World Journal of Advanced Research and Reviews, 2022, 16(3), 711-722. Article DOI: https://doi.org/10.30574/wjarr.2022.16.3.1381

Copyright © Author(s). All rights reserved. This article is published under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0), which permits use, sharing, adaptation, distribution, and reproduction in any medium or format, as long as appropriate credit is given to the original author(s) and source, a link to the license is provided, and any changes made are indicated.


All statements, opinions, and data contained in this publication are solely those of the individual author(s) and contributor(s). The journal, editors, reviewers, and publisher disclaim any responsibility or liability for the content, including accuracy, completeness, or any consequences arising from its use.

Get Certificates

Get Publication Certificate

Download LoA

Check Corssref DOI details

Issue details

Issue Cover Page

Editorial Board

Table of content

Copyright © 2026 World Journal of Advanced Research and Reviews - All rights reserved

Developed & Designed by VS Infosolution